Skip to content

Products

Room Alert 32S Monitor

The Room Alert 32S is AVTECH’s flagship environment monitor, offering the highest security features in our product line, including protocols like HTTPS, TLS and SNMP v3.

Like our Room Alert 32E, this model is packed with the most capacity for the most sensors. It monitors temperature, humidity and its own main-vs-battery-power status. With room for 30 sensors/accessories each and the capacity to toggle multiple low-voltage electrical devices, it’s got your environment covered.

When conditions exceed your thresholds, Room Alert notifies you right away so you can act quickly.

• Send email and text messages right from the device.
• Trigger the warning LEDs and siren sound on a Light Tower.
• Pair with RoomAlert.com (or other compatible platforms) for even more alerting capabilities.

$2,079.00 exc. GST

Share
Tweet
Save
Email
SKU: RA32S-DAP-RAS Tag:
Loading...

Room Alert 32S Monitor

Unique to our product line, the Room Alert 32S features these secure protocols:

– View the built-in web interface over HTTP or HTTPS.
– Push data to your RoomAlert.com account over HTTPS.
– Send alert notifications from the device over your TLS mail server.
– Integrate the device into your preferred SNMP program over SNMP v3. (SNMP v1 traps and SNMP v2c also available)
– Update your firmware with your authenticated username & password.

Like the Room Alert 32E, this unit is packed with the most sensing capacity: it monitors your facility for temperature and humidity and boasts a generous capacity for up to 26 more sensors each. The standard Room Alert 32S package includes 1 Digital Temperature & Humidity Sensor (25′) to help monitor temperature, humidity, heat index and dew point, plus 1 Digital Temperature Sensor for more temperature monitoring where you need it. 4 additional ports allow you to toggle low-voltage electrical devices, such as an AC units, fans, alarm panels and the warning LEDs/siren sound on a Light Tower.

This feature-packed model also houses an internal battery backup that can supply up to 15 minutes of power to the device. Should main power falter, that extra uptime allows the unit to execute critical notifications and actions. A dedicated internal power sensor watches the battery back up, letting you know if the device is on main or battery power.

The Room Alert 32S fits 1U of rack space in a server cabinet, but can also hang from a ceiling or on a wall from its rotating rack wings. Perfect for areas requiring comprehensive coverage, this unit is at home in data centers, warehouses and any space requiring eyes on a wide variety of conditions—or on the same condition in multiple targeted locations.


Use Room Alert 32S on its own or pair it with these powerful platforms!
– RoomAlert.com
– Room Alert Manager
– 3rd-party SNMP or JSON

Trigger alerts, reminders and “all-clears” in response to environmental thresholds that you set.

Receive alerts in the best format for you!- Email
– Text message
– Visual/audible signal
– HTTP post
– SNMP trap


View sensor readings on an easy-to-read web interface—over the Internet or on your local network.


Compile, graph and download historical sensor data to spot trends in your environment.

Power Room Alert by PoE or with included 5V power adapter.

Specifications

Room Alert 32S Specifications
This list applies to both the Room Alert 32S and Room Alert 32E models.

Feature Description
Internal temperature sensor Condition monitored Indoor ambient temperature
Type Digital
Range -40 to 185 F (-40 to 85 C)
Accuracy +/- 2° C
Resolution 0.03125° C
Readings Numeric values in Fahrenheit or Celsius
Feature Description
Internal humidity sensor Condition monitored Indoor relative humidity (RH), non-condensing
Type Digital
Range 5% – 85% RH
Accuracy +/- 4.5% RH at 5 to 59% RH
+/- 6.5% RH at 60 to 95% RH
Resolution 0.333% RH
Readings Numeric values in % RH
Internal humidity sensor Condition monitored Power status of the Room Alert 32S
Type Switch
Range Open/Closed
Readings Battery power”/”Main power/td>
External sensor & accessory ports 8 digital sensor ports (RJ-11)
16 switch sensor ports (screw terminal blocks)
2 analog sensor ports (screw terminal blocks)
2 relay output ports (screw terminal blocks)
2 Light Tower & Relay Adapter ports (RJ-11)
Power & connectivity ports 1 5V barrel-connector power jack
1 RJ-45 Ethernet port (PoE-enabled)
Power supply AVTECH 5V power adapter (100/240 VAC, 50/60 Hz, RoHS)
or PoE (IEEE802.3af compliant)
Dimensions Height 1.75″
Depth 3.75″
Width 14″ (without rack-mount wings)
19″ (with rack-mount wings)
Operating tolerances Temperature -40 to 185 F (-40 to 85 C)
Humidity 5% – 85% RH, non-condensing
Do not place Room Alert monitors inside refrigerators/freezers—these are condensing environments.

Compatible Products

Room Alert 32S Compatible Products

Compatible monitoring platforms
Compatible sensors & accessories
Compatible power adapters

Compatible monitoring platforms

You may access your Room Alert 32S through the compatible platforms below. For more information, please see our FAQ, The Differences Between Room Alert Monitoring Platforms.

Room Alert’s built-in web interface
RoomAlert.com Account
Room Alert Link software
Room Alert Manager software
Replaces Device ManageR.
Device ManageR software
Device Discovery utility
3rd-party off-the-shelf SNMP program
3rd-party custom HTTP/JSON application

Room Alert “S” models are not compatible with AVTECH’s Device ManageR software or Device Discovery utility.

Compatible sensors & accessories
This list also applies to the Room Alert 32E model.

Room Alert’s built-in web interface Matching ports on this model
Any AVTECH digital sensor Built-in 8 digital ports
Any AVTECH switch sensor
Any 3rd-party device with open/closed dry contacts
Built-in 16 switch ports
Any AVTECH analog sensor
Any 3rd-party analog sensor that outputs 1 to 5 VDC
Built-in 2 analog ports
External Add up to 8 more analog ports.
Here’s how: Put a Digital Temperature & Analog Sensor in each of your device’s built-in digital ports
3rd-party low-voltage electrical devices Built-in 2 relay output ports
External Add up to 2 more relay output ports.
Here’s how: Put a Light Tower & Relay Adapter in each of your device’s built-in LTA ports.
Then add up to 8 more relay output ports.
Here’s how: Put a Relay Switch in each Light Tower & Relay Adapter.
AVTECH’s Light Tower & Relay Adapter (LTA) Built-in 2 LTA ports
AVTECH’s Light Tower
AVTECH’s Relay Switch
External Add up to 2 compatible ports.

Here’s how: Put a Light Tower & Relay Adapter in each of your device’s built-in LTA ports.

Compatible power adapters

Always use an AVTECH 5V power adapter with your Room Alert. Others will void your warranty and may damage your unit.

AVTECH’s 5V standard power adapter (USA, Canada, Japan)
AVTECH’s 5V international power adapter
AVTECH’s 5V C14 power adapter